Siemens SICAM P850: The Digital Solution for Power Quality Analysis

In the dynamic landscape of power systems, the Siemens SICAM P850 emerges as a digital powerhouse, revolutionizing the realm of power quality analysis. This cutting-edge device is engineered to unravel the intricacies of power quality, providing a comprehensive and insightful solution for industries seeking precision and efficiency in their electrical operations.

The Siemens SICAM P850 isn’t just a mere instrument; it’s a game-changer. With its advanced capabilities, this digital marvel goes beyond conventional power meters. It delves into the nuances of power quality, offering a detailed analysis that empowers industries to optimize their electrical systems. From voltage fluctuations to harmonics, the SICAM P850 equips businesses with the knowledge they need to enhance reliability, mitigate risks, and ensure a seamless and efficient power supply. Join us on this journey as we explore the transformative potential of SICAM P850 in shaping the future of power quality analysis.

Introduction to Siemens SICAM P850 as a Digital Solution for Power Quality Analysis

The SICAM P850 Power meter device is a versatile measuring instrument designed for the acquisition, visualization, evaluation, and transmission of electrical variables. These variables encompass alternating current, alternating voltage, frequency, power, harmonics, and more. The device offers flexibility in outputting measured data to a PC or system control through communication interfaces, and it also features a display for on-site data presentation. Beyond its monitoring capabilities, the all-in-one functionality of the SICAM P850 extends to recording. Users can record measured values at customizable time intervals, utilizing the device’s measurement and fault recorders for a comprehensive overview of electrical performance.

Special Features Of the SICAM P850 Power Device

  • The storage capacity for recorder data is 2 gigabytes.
  • Acquiring measured values in accordance with the power quality measurement standard IEC 61000-4-30.
  • Functionality for mean value and fault recording.
Siemens SICAM P850

Applications of Siemens P850 Meter 

The SICAM P850 device is applicable in both single-phase and three-wire and four-wire systems, including those with a neutral conductor. Its utilization extends to scenarios where a thorough measurement of supply quality is essential, whether in power utilities or various industrial and trade sectors.

Power Quality

Ensuring power quality in a phase of energy transition

The rise in power feed-in from renewable sources presents novel challenges for municipalities and distribution system operators.

Ensuring a consistent supply of electrical power remains the foremost priority for any grid operator. To mitigate fluctuations in power quality and prevent disturbances, it is imperative to tailor and enhance grid monitoring, control, and automation systems across all voltage levels. 

Technical specification of Siemens SICAM P850 

Input measuring circuits

  • Four times alternating voltage and three times alternating current (maximum 10A).

Measured Variables

  • Frequency of power, active power, reactive power, apparent power, power factor, active power factor, and phase angle.
  • Total harmonic distortion (THD) of alternating voltage and alternating current.
  • Root Mean Square (RMS) values for alternating voltage and alternating current.
  • Voltage and current imbalance in alternating systems.
  • Harmonics in alternating voltage and current up to the 40th order.

Operation and display

  • A full graphic display including operation via 4 function keys
  • 4 LEDs for state and system messages
  • Integrated web server to interact with PC via HTML pages

Time synchronization

  • Via Ethernet: SNTP client (Simple Network Time Protocol)
  • Via Fieldbus
  • Internal Real Time Clock (RTC)

Auxiliary voltage

  • DC 24 – 250 V
  • AC 110 – 230 V, 50/60 Hz

Housing specification

  • Plastic housing for DIN rail mounting, optional panel mounting, protection class max. IP51
  • Dimensions: 96 x 96 x 100 mm (W / H / D)

Customer Benefit

  • Consistent measured values, independent of the manufacturer, are achieved through the utilization of standard measurement methods outlined in the IEC 61000-4-30 standard.
  • Ensuring interoperability is accomplished through the utilization of standard interfaces and protocols, including IEC 61850, Modbus, and IEC 60870-5-103.
  • Convenient operation is facilitated through the integrated web server, allowing for parameterization, diagnosis, evaluation, and reporting.
  • Thorough capture of pertinent network parameters.

Numerous electronic devices and automation systems within industrial production facilities are susceptible to voltage fluctuations and power supply dips, frequently triggered by the abrupt integration of energy sources like renewables and significant energy consumers. Additionally, the production systems may generate faults that are fed back into the distribution network. The potential consequence? Plant shutdowns and a loss in production. The solution? Prioritizing power quality. Constant measurement and analysis of power quality are imperative to promptly identify unforeseen risks, safeguarding against potential disruptions in industrial operations.

Conclusion:

In conclusion, the Siemens SICAM P850 emerges as a cutting-edge digital solution that transcends the traditional boundaries of power quality analysis. Its multifunctional prowess in acquiring, visualizing, evaluating, and transmitting electrical variables marks a significant leap forward for industries seeking precision in their electrical operations. The device’s ability to handle a spectrum of measured variables, including alternating current, voltage, frequency, power, and harmonics, positions it as a versatile asset. Beyond monitoring, the SICAM P850’s recording function provides a dynamic and customizable approach, allowing industries to analyze electrical performance over time with the utmost granularity.

As we navigate the evolving landscape of power systems, the SICAM P850 stands as a beacon of innovation, promising improved reliability and efficiency. Its seamless integration with communication interfaces and display features amplifies its user-friendly nature. In essence, the Siemens SICAM P850 not only addresses the current needs of power quality analysis but also sets the stage for a future where digital solutions redefine the standards of precision and insight in the realm of electrical operations.

For the most competitive offer on the Siemens SICAM P850 Power meter device, reach out to Reliserv Solution, your authorized supplier and channel partner for Siemens numerical relays, automation products, power quality meters & instruments, MV switchgear spares, and PSS SINCAL Software. Operating from Mumbai, Maharashtra, we stand as the premier supplier and exporter of Power Quality Meters products. Our expertise extends to providing a diverse range of services and customized solutions for industries and panel builders. Feel free to contact us at +917506112097 or email your requirements to [email protected]. Delve into our extensive Siemens Power Quality Measurement collection by clicking here to explore the variety of high-quality products we offer.