Substation Automation Solutions for Pharma Sector
Substation Automation Solutions for Pharma Sector
We offer Substation Automation Solutions for Pharma Industries for boosting the efficiency of operations and avoiding unnecessary breakdowns. We also provide training in our new installation for operation and maintenance staff of client to better understanding technology, thus increasing the plant efficiency.
Our Substation Automation Solutions for Pharma industries are as follows:
Engineering Solutions:
- Auto Transfer Scheme for Incomer and DG switchover
A bus transfer system is designed to provide process continuity to the loads attached to a motor bus while transferring the bus from one source to another. A successful bus transfer under contingent conditions provides immense value and benefits to continuous process operations that cannot afford an interruption of power supply to plant auxiliaries.
We are experienced in designing and implementing such schemes for substations. This can be done as a retrofit in existing panels or supplied as a new panel as per station condition and requirement.
- Load Shedding scheme
During overloads in the mains, the load shedding applied to interruptible loads is often the only solution to keep the industries in operation. Normally, in such cases, non-critical loads that are earlier identified are tripped automatically to avoid interruption of critical loads and induced penalties when power is being drawn from the grid.
We offer a range of products and solutions from Siemens/Schneider for these critical operations based on Current, Power or frequency for load shedding.
- Power System Studies and Relay Coordination’s
Relay coordination study and analysis is performed to make sure that safety operation of the system are functioning correctly and to avoid the nuisance tripping, as protection is a major concern in any industry and they rely on protective devices for the same.
The aim of a coordination study is to determine the characteristics, ratings, and settings of overcurrent protective devices which will ensure that minimum unfaulty load is interrupted when protective devices isolate a fault or overload anywhere in the system.
- Protection System Upgradation/ Retrofits with Modern Numerical Relays
Older relay usually outdated, are supposed to be replaced in industries to avoid mal tripping and ease operations in a plant. We offer
- Replacement of old Electromechanical Relays with Numerical Relays
- Replacement of Outdated Numerical Relays with Latest Models
- Upgradation of existing SCADA system
- Integration of additional Devices into existing SCADA
Our team is experienced in carrying out such services in all types of industries, from data collection, to upgradation and handing over.
- Outage Loss Monitoring meters
Outages can cause losses in an industry. These outages are often classified as Controlled outage (normal shutdown) or uncontrolled outage (fault trip). Our meters are specifically designed to register such outages in Minutes or seconds and report to automation system. This helps in evaluation of losses on per day, per month or per year basis.
Testing and AMC Solutions
- Testing of Substation Equipment’s
Testing of substation equipment’s is a critical task with several standards defined for each equipment for testing. This ensures a proper operation in the substation in the team of experts can give you all kinds of Testing and commissioning of Substations. We can work all across the voltage levels LV, MV, HV and EHV. We have our own advanced testing equipment to carry out necessary testing of the substation and to get the work done quickly without depending on anybody.
- Maintenance for Breakers
Service life of a breaker is a parameter linked to maintenance of the breaker. Servicing reduces the issues of aging with the breaker and maintains smooth operation of the breaker during the life time.
Explore the comprehensive range of Automation Solutions offered by us Click Here!